Fike fm 200 manual pdf

Fike clean agent containers are used in fire extinguishing systems to store. Kidde fenwal fm200 fire suppression systems are environmentallyfriendly and a halon 1 alternative. Pdf fike fire alarm manual cheetah trouble codes read. Fm200 fire suppression system the grasshopper group. The sr200hfc227ea gas system manual is a proprietary data of sri. The gate must not exceed 12 feet in length and weigh more than 300 pounds please see technical specifications on page x. Sr200hfc227ea gas suppression system engineering manual.

Our clean agent fire protection system, using dupont fm200 as thefm200 fe227ea heptafluoropropane cf3chfch3extinguishing agent, leaves no residue and doesnt require. The primary extinguishing mechanism of fm200 is heat absorption, with a secondary chemical contribution from the thermal decomposition of fm200 in the flame. Specification for a fm200 national fire alarm code. It includes cylinder, dip tube, discharge valve with pressure gaugeswitch, manual level release and the solenoid electrical actuator. Design, installation maintenance manualfm200fike 5143vky9x9nj. Read pdf fike cheetah fire panel manual fike cheetah fire panel manual fire alarm control panel fike cheetah xi ground fault testing and diagnostic facp. The fm 200 system is most effective when used with a detection system to introduce the clean agent rapidly.

A clean agent fire suppression valve controls the pressure within. The fm200 fire suppression system contains sensitive detectors that can detect even the smallest fires. Fike shppro is the reliable, conventional fire suppression system. Learn how the the fm200 clean agent fire protection system hfc227ea leaves. Fm200 leaves no residue or oily deposits on delicate electronic equipment, and can be removed from the protected space by ventilation. The detection circuits can be configured using cross, counting, independent or. Safe for use in occupied areas at the design concentration, the system helps protect critical infrastructure and delivers effective asset protection. Reproduction of the whole or any part of this manual other than the support of the equipment for which is published is not allowed without the permission in writing by sri. Unmatched in the industry for sheer versatility and ease of installation, this singlehazard control system boasts incredible power and can be easily configured for use within a wide range of industries and fire suppression applications. Fm200 is thermally and chemically stable, but without the extremely long atmospheric lifetimes associated with other proposed halon replacements.

Fm200 is a colorless, nontoxic gas perfectly suited to protect high. The fm200 system is most effective when used with a detection system to introduce the clean agent rapidly. The control unit shall be approved by underwriters laboratories, inc. The gca is designed to operate in all fike clean agent. Fm200 clean agent fire suppression system physical properties chemical name heptafluoropropane cf3chfcf3 molecular weight 170. Introducing the new fike impulse valve used with fike. Electric manual actuation impulse valve operator ivo for detailed. And it discharges in 10 seconds or less, extinguishing a fire quickly and. The shppro fire suppression system is also built for easy installation, making it versatile and easy to manage. Maintenance manual for the clean agent fire extinguishing system employing fm200 shall be submitted after complete installation.

This detection system is used to actuate a single, fixed fire suppression or alarm system based on inputs received from fire detection devices. Refer to fike hfc227ea fm200 instruction manual for liquid level indicator lli, pn 06107. The atmospheric lifetime of fm200 has been determined to be 36. The system is designed and installed in accordance. The clean agent fire extinguishing system shall consist of fm 200, agent cylinders, 1800. Whilst every care has been taken to ensure that the contents of this document are correct at time of publication, fike shall be under no liability whatsoever in respect of such contents.

The mighty mule gate opener is designed for installation on a pulltoopen single leaf gate gates that open into the property. Level readout is obtained by simply removing the protective cap and pulling out a calibrated tape until magnetic interlock with the float. Handle in accordance with good industrial hygiene and safety. Maintenance manual for the clean agent fire extinguishing system employing fm 200 shall be submitted after complete installation. Pyrochem has integrated stateoftheart fire detection technology and cleanagent chemistry to provide cost effective fire protection for applications containing highvalue critical data and sensitive equipment. If you are searched for a ebook fike fire alarm manual cheetah trouble codes in pdf form, then you have come on to the loyal site. So that if want to load fike proinert installation fire suppression manual pdf, in that case you come on to the loyal site. Fm200 fire suppression system costeffective protection for. Fm200 hfc227ea is formed from the elements carbon, fluorine and hydrogen cf3chfcf3heptafluoropropane. Shppro is the reliable, conventional fire suppression system for smaller applications. Fm200 fire suppression system costeffective protection. About this manual this manual is a comprehensive guide that contains all the information necessary to design, install and maintain the fm200 engineered extinguishing system. Design, installation maintenance manualfm200fike gases. The clean agent fire extinguishing system shall consist of fm200, agent cylinders, 1800.

A 360psi modular system is a single cylinder system using welded cylinders from 67 to 592 lbs. This microprocessorbased fire detection system can be easily configured for use within a wide range of industries and fire suppression applications. Acoma drive, suite 106 scottsdale, az 85260 usa telephone. Manual or automatic actuators are available for release of the agent into the hazard area. The panel shall accept input from the following types of equipment used to make up the system. Maintenance manual, pn 06202 or 06215 and the fike flow calculation. These systems offer the most versatile clean agent suppression systems available for any business, big or small. Design, installation maintenance manualfm200fike free download as pdf file.

The fm 200 fire suppression system contains sensitive detectors that can detect even the smallest fires. Fm200 fe227ea heptafluoropropane cf3chfch3 for speed in suppressing fires, reducing damages, saving on floor space and allowing visibility, fike is the clear choice. Fike fm 200 clean agent fire suppression system with the shp pro control panel fm 200 system w shp pro specification page 2 of 8 pn. The ansul fm200 clean agent fire suppression system is approved by factory mutual fm and listed by underwriters laboratories ul for class a, b and c fires. Our clean agent fire protection system, which includes the use of hfc227ea and fm200, leaves no residue and doesnt require costly cleanup, unlike sprinklers and other fire protection systems. Page 2 fikes policy is one of continual improvement and the right to change a specification at any time without notice is reserved. Factory mutual fm fm200 systems are manufactured in strict accordance with the internationally recognised quality assurance standard, bs en is0 9000 and approved to iso 9001 fm200 extinguishing system units are to be designed, installed, inspected, maintained, tested and recharged. Fm200 fire suppressant can be safely used where people are present. About this manual this manual is intended to be a complete reference for the installation, operation, and service of the fike single hazard panel professional shp rpro fire alarmsuppression control system. Fike fm200 clean agent fire suppression system with the shp pro control panel fm200 system w shp pro specification page 2 of 8 pn. In applications where space is at a premium, fm200 fire suppression systems are the superior choice. For ecaro25 systems, the maximum operating temperature is 120f 49c. The fm200 agent is stored in cylinders as a liquid and pressurized with nitrogen, saving huge amounts of storage space.

Fm200 fire suppressant hfc227ea can be safely used where people are present. This clean agent is very safe for occupied spaces and nontoxic when used in accordance with nfpa standard 2001. Kidde fenwal fm 200 fire suppression systems are environmentallyfriendly and a halon 1 alternative. This reliable fire detection workhorse is compliant with the ul 864 standard, rounding out a list of features which make the shppro the leader in conventional fire detection and fire protection.

For speed in suppressing fires, reducing damages, saving on floor space and allowing visibility, fike is the clear choice. Fm200 total flooding fire suppression system general the fm200 total flooding fire suppression system is an engineered system utilizing a fixed nozzle agent distribution network. Once the fm 200 fire suppression system discovers a fire in the room, the fm 200 system can respond in a matter of seconds, flooding the area with the extinguishing agent and preventing the fire from getting out of control. How to silence and reset a cfp fire alarm panel a short video explaining how an authorised user can silence and reset a fire alarm condition on a ctec cfp conventional fire. The system is designed and installed in accordance with the national fire protection association nfpa standard 2001, clean agent fire extinguishing systems. Live fm 200 system discharge fm 200 fire suppression systems go to.

When used at standard design concentrations, it is safe for occupied spaces. Once the fm200 fire suppression system discovers a fire in the room, the fm200 system can respond in a matter of seconds, flooding the area with the extinguishing agent and preventing the fire from getting out of control. And it discharges in 10 seconds or less, extinguishing a fire. Sr200hfc227ea engineering manual sri issued sept 24, 2010, rev. Design, installation maintenance manual fm200 fike free download as pdf file. Refer to fike hfc227ea fm 200 instruction manual for liquid level indicator lli, pn 06107. Most common metals, such as aluminum, brass, steel, cast iron, lead, stainless steel, and copper, as well as rubber, plastic, and electronic components, are. January, 2008 3 the installing contractor must have a minimum of five 5 years experience in the design, installation and testing of clean agent, or similar, fire suppression systems.

771 1359 1020 74 680 837 826 470 657 97 1439 1467 190 1143 1097 1485 950 64 1202 1012 744 973 123 517 477 1048 960 607 350 824 77 1040 1064 288 331 1288 1126 892 23 196 252 533 790 394 565